Product Brief: Powereta™ – Single Output High Current Double-P Quarter Brick
Powereta™ iQP Series Double-P Quarter Bricks
48V Input, 3.3V/70A and 2.5V/80A Output
The Powereta™ iQP Series offers an industry standard extra
output pins (Double-P) quarter brick high current power module
with true useable output power. Its 89% to 91.5% full load
efficiency and superior thermal performance make the Powereta™
Series of power modules ideally suited for tight space and power-
hungry applications in demanding thermal environments. This
rugged building block is designed to serve as the core of your high
reliability system. A wide output voltage trim range, -20 to +10%,
and remote sensing are standard features enhancing versatility.
TDK Innoveta Base
Product Code
iQP48070A033V
Input
Voltage
36-75V
Output
Voltage
3.3V
Output
Current
70A
Efficiency
70%Load
92.5%
Efficiency
100%Load
91.5%
Features
•
•
•
•
•
•
•
•
RoHS Compliant
Standard Double-P Quarter Brick Pinout
Size: 2.28” × 1.45” × 0.5”
Up to 80A of output current
iQP48080A025V
36-75V
2.5V
80A
90.5%
89%
Power density: up to 140W / in3
Maximum efficiency – up to 93.5%
Full load efficiency: 89% to 91.5%
Output power – up to 231W in high
ambient temperature, low airflow
environments with minimal derating
Wide output voltage trim range
Industry standard output voltage trim
Basic insulation – 1500Vdc
Typical Performance
Input Characteristics
Operating input range
Transient input voltage
Turn-on voltage
Turn-off voltage
Maximum input current
36-75V
100V
34.4V
32.3V
8 A
100mS max
•
•
•
•
•
•
•
•
Input 0-75V, Io,max
Output Characteristics
Output voltage tolerance
+/- 3.3% max
Over line, load, and
temp to end of life
Io,max
Over rated input
Over rated load
On/Off to 90% Vo
%Vo,nom
20MHz bandwidth
Load step 25% of
Io,max
Choice of remote on/off configuration
Remote sense
Constant switching frequency
Latched output over-voltage protection
Auto-recovery full protections:
Efficiency
89% to 91.5%
1 mV
Line regulation
Load regulation
Start-up time
Output voltage adjustment
Output ripple
Dynamic response
Transient voltage
Recovery time
1 mV
25 ms
80%-110%
25 - 40 mVp-p
o Input under and over voltage
o Output over-current
o Output short circuit
o Thermal limit
150 – 200 mV
500 - 650 µS
270 kHz
slew rate =0.1A/us
Ripple frequency
Fixed
Protection
Output over-current
Short circuit
110% of Io,rated
Continuous
protection
121% of Vout,nom
126C
Auto-recovery hiccup
Auto-recovery hiccup
•
UL 60950 (US and Canada), VDE 0805,
CB scheme (IEC950) Safety markings
and CE Mark (EN60950)
Output over-voltage
Thermal shutdown
Latching
Auto recovery with
hysteresis
•
•
•
•
•
Optional 0.110”, 0.145”, 0.180” pin length
Optional non-latching OVP protection
EMI: CISPR 22 A or B with external filter
Multiple patents pending
Environmental
Operating temperature, Tc
-40C to 119C
See full datasheet
ISO9000 certified manufacturing facilities
℡ (877) 498-0099
©2006 TDK Innoveta Inc.
1/2
iQP 2.5V to 3.3V Product Brief 4/20/2006
|
Tascam Car Video System HD R1 User Manual
Tektronix All in One Printer 740 User Manual
Topfield Satellite TV System TF 6000 PVR User Manual
Toshiba Cash Register MA 215 User Manual
Tripp Lite Network Cables N001 003 BK R User Manual
Tripp Lite Surge Protector LS604WM User Manual
Troy Bilt Snow Blower 42021 User Manual
Velodyne Acoustics Speaker VA 12 15X User Manual
Vulcan Hart Oven VCG10H ML 126836 VCG10F ML 126837 VCG20H ML 126838 User Manual
Wagner SprayTech Paint Sprayer W 867 E User Manual